01-Feb-2017, 09:16 AM (This post was last modified: 01-Feb-2017, 08:07 PM by Tom BD Bad.)
I just tried to flash silverxxx firmware to my H8 (blue) board, Downloaded and installed drivers, programs and everything including the 'not necessary' GigaDevice. Connected DAT to SWCLK , CLK to SWDIO , and GND to GND on ST-link, (as per instructions for blue board) opened 'H8 blue' in uVision, built Target, opened 'ST-link Utility,' plugged battery in and connected ST to USB.
When I hit connect the Utility threw an error and said to change 'Connect Under Reset' in Target -> Settings... so I did.
As a result it then changed 'reset mode' to 'Hardware Reset.' I then continued following instructions followed to Target -> Option Bytes, changed protection to 'Level 0' and hit Apply, then the Utility crashed, I looked round and saw that the LED's on the board were off! Thinking surely battery should have lasted longer than that...!?
I closed ST Link Utility, changed the battery and started again, and the same thing happened, LED's off utility crashed. Only now when I change the battery no LED's come on at all...
even though ST util threw the error when I changed the protection, it now shows me the code, recognizes when battery is connected and allows changing the settings. But if I try to connect straight away it says it can't, I have to unplug the ST link dongle restart ST util and go Target -> Settings, this makes the led on the dongle to go from red to flashing blue and red, then when I confirm settings it goes solid blue, and back to red when I disconnect. When I try to erase with Keil the led goes blue again, but it throws a communication error, Tried to 'download' as well, but that also threw an error.
No leds even when USB unplugged, no bind or response from TX input, have I killed it?
When I hit connect the Utility threw an error and said to change 'Connect Under Reset' in Target -> Settings... so I did.
As a result it then changed 'reset mode' to 'Hardware Reset.' I then continued following instructions followed to Target -> Option Bytes, changed protection to 'Level 0' and hit Apply, then the Utility crashed, I looked round and saw that the LED's on the board were off! Thinking surely battery should have lasted longer than that...!?
I closed ST Link Utility, changed the battery and started again, and the same thing happened, LED's off utility crashed. Only now when I change the battery no LED's come on at all...
even though ST util threw the error when I changed the protection, it now shows me the code, recognizes when battery is connected and allows changing the settings. But if I try to connect straight away it says it can't, I have to unplug the ST link dongle restart ST util and go Target -> Settings, this makes the led on the dongle to go from red to flashing blue and red, then when I confirm settings it goes solid blue, and back to red when I disconnect. When I try to erase with Keil the led goes blue again, but it throws a communication error, Tried to 'download' as well, but that also threw an error.
No leds even when USB unplugged, no bind or response from TX input, have I killed it?